KHS Hygiene Flush Boxes
KHS Hygiene Flush Box PRO with flow sensor, single port, figure 689 03 007

KHS Hygiene Flush Box PRO with flow sensor, single port

figure 689 03 007

  • particularly suitable for buildings with special hygiene requirements
  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • Single port (water exchange group) for cold drinking water (PWC)
  • Interval, time and volume based flushing
  • Temperature and use based flushing (only possible with additional temperature sensor Pt1000)
  • digital commissioning and maintenance assistant
  • analysis and log readout via WLAN and USB
KHS Hygiene Flush Box PRO with flow sensor, double port, figure 689 03 008

KHS Hygiene Flush Box PRO with flow sensor, double port

figure 689 03 008

  • particularly suitable for buildings with special hygiene requirements
  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • double port (water exchange groups) for connection of e.g. PWC and PWH
  • Interval, time and volume based flushing
  • Temperature and use based flushing (only possible with additional temperature sensor Pt1000)
  • digital commissioning and maintenance assistant
  • analysis and log readout via WLAN and USB
KHS Hygiene Flush Box PURE, single port, figure 689 03 005

KHS Hygiene Flush Box PURE, single port

figure 689 03 005

  • Especially suitable for time-controlled interval flushing operation in small buildings
  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • Single port (water exchange group) for cold drinking water (PWC)
  • manual commissioning on the device by hand
  • interval controlled flushing
  • up to 100,000 event entries to verify use as intended (readout via USB)
KHS Hygiene Flush Box PURE, double port, figure 689 03 006

KHS Hygiene Flush Box PURE, double port

figure 689 03 006

  • Especially suitable for time-controlled interval flushing operation in small buildings
  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • double port (water exchange groups) for connection of e.g. PWC and PWH
  • manual commissioning on the device by hand
  • interval controlled flushing
  • up to 100,000 event entries to verify use as intended (readout via USB)
KHS Hygiene Flush Box LITE with flow sensor, single port, figure 689 03 009

KHS Hygiene Flush Box LITE with flow sensor, single port

figure 689 03 009

  • particularly suitable for safety-sensitive buildings
  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • Single port (water exchange group) for cold drinking water (PWC)
  • no integrated controller logic (control via direct connection of all components to BMS (24 V/4-20 mA)
  • Interval, time and volume based flushing measures possible (depending on external flushing logic)
  • Temperature based flushing possible (depending on external flushing logic) (only possible with additional temperature sensor)
KHS Hygiene Flush Box LITE with flow sensor, double port, figure 689 03 010

KHS Hygiene Flush Box LITE with flow sensor, double port

figure 689 03 010

  • particularly suitable for safety-sensitive buildings
  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • double port (water exchange groups) for connection of e.g. PWC and PWH
  • no integrated controller logic (control via direct connection of all components to BMS (24 V/4-20 mA)
  • Interval, time and volume based flushing measures possible (depending on external flushing logic)
  • Temperature based flushing possible (depending on external flushing logic) (only possible with additional temperature sensor)
KHS HS2<sup>®</sup>, hygiene-flushing box, double port, incl. cover panel, figure 689 03 002

KHS HS2®, hygiene-flushing box, double port, incl. cover panel

figure 689 03 002

  • to avoid stangnation acc. to standards and guidelines
  • allows water exchange with turbulent flow in drinking water pipes up to DN 50
  • operation via Bluetooth with HS2®-App (Bluetooth can be switched off)
  • double port (water exchange groups) for connection of e.g. PWC and PWH

KHS Hygiene Flush Box

The KHS Hygiene Flush Box helps to ensure the intended use in drinking water installation through automatic flushing measures. The time, temperature and volume parameters of the water exchange can be controlled. The new generation combines surface- and flush-mounting in a single device. All in one!

A matching controller concept for every building usage

The PRO, PURE and LITE versions let you select the optimal controller concept for the type of building use. Only the scope of function which is needed for the building in question will be selected. The KHS Hygiene Flush Box can be installed surface-mounted or flush-mounted without additional accessories. Thanks to the innovative housing concept, all versions of the Hygiene Flush Box can be either flush-mounted so that they integrate almost invisibly into the wall structure or elegantly surface-mounted on the wall.

An economically viable version for every building
PRO PURE LITE
Hospitals (✓)
Care homes
Geriatric care
Residential buildings
Halls of residence
Hotels
Detention centres (✓)
Accommodation blocks (e.g. military) (✓)
Schools
Sports facilities
Nurseries
Laboratories
Industrial buildings (✓)
Department stores (✓)
Swimming pools
Interim solutions
(✓) = no internal flushing logic

All advantages of the KHS Hygiene Flush Box at a glance

Please click on the sections for more information

Kemper Flushtool

Our Flushtool supports you in selecting the components for ensuring the required water exchange for drinking water installations and installations in conjunction with firefighting water transfer in accordance with DIN 1988-600.

Go to the Flushtool